Welp, winter heating season is quicklyÂ
approaching (in the northern hemisphere anyway) which means that many of us are firing up ourÂ
heating systems for the first time in many months and hoping for the best. Have you ever wonderedÂ
why your furnace makes the noises that it does? And how come it seems to work inÂ
distinct steps? Whatâs a heat exchanger? Why do I need to be worriedÂ
about carbon monoxide poisoning? Why do we use furnaces at all? Great questions!Â
So great that Iâm making a video to answer them. Now first, weâre gonna be talking about theÂ
typical forced-air gas-fired North American  heating system in this video because thatâs whatâsÂ
common where I live and what I have access to.  Pretty much every small to medium-sizedÂ
building over here constructed in the last  half century or so in a winter climate has at least oneÂ
of these providing it with heat. If youâre used to a heating system with a central boiler andÂ
radiators, well this ainât that. Those arenât exactly rare in North America, but are typicallyÂ
limited to older buildings that were constructed  before we became addicted to air conditioning. Ever since central air conditioning became common, weâve settled on ducted systems like this where a furnace acts as both the heat source for winter months and air handler for the air conditioner in the summer months. Letâs start by asking what the basicÂ
job of the furnace is. You might say, well obviously itâs to provide heat for a livingÂ
space - and youâd be more-or-less right! But more specifically, its job is to safely release as much of theÂ
heat energy contained in a combustible fuel that it can into the living space and distributeÂ
it with the aid of a blower fan and ductwork. Nearly everything in the furnaceÂ
is designed around safety, and its sequence of operations is performedÂ
specifically to prove the integrity and functionality of each of its components before itÂ
allows itself to run. If it fails its own tests, it locks itself out and youâll need to call yourÂ
local HVAC company. Better that than be dead! Weâll go over that sequence of operations as wellÂ
as the components themselves shortly but first,  letâs discuss why we use these things. These seem to invite a sort of bafflement in those who donât live in North America. If a boiler is what youâre used to, well that makes sense, but quite often Iâve run across folks who seem to think our furnaces are somehow inefficient machines. Not at all, these are incredibly efficient. This particular furnace is able to capture 96% of the heat energy in a fuel. Thatâs excellent,Â
but some models get even more than that! Hi, itâs me from the future with an embarrassingÂ
correction. So weâre about to talk about the AFUE or âA-fewâ which stands for annual fuelÂ
utilization efficiency. And for this furnace Itâs 95. Not 96. I had countless opportunitiesÂ
to look at this label before now, alas I took none of them. And my memory failed me. So for the rest of this video, if I say â96â I probably meant 95. Anyway, back to the AFUE. Itâs measured as a more-or-less yearly averageÂ
to help account for the differences in efficiency  at start-up and shut-down. During a steadyÂ
heating state itâs actually slightly higher.  Being able to get 96% of the heat energy availableÂ
in a fuel into the living space is tremendous, but even the worst natural gas furnaces on the marketÂ
have at least an AFUE of 80. A long time ago I made a video specifically about the rationaleÂ
behind burning fuel for space heating, but this is essentially it. Furnaces excel at burning fuelÂ
and capturing nearly everything we can from it. That said, theyâre probably (and, hopefully) onÂ
their way out as we move towards electrification.  Now, we donât typically use electric resistiveÂ
heating to heat entire homes because,  while electric heat is itself 100% efficient,Â
electrical generation is not. And even if it were, the electrical requirements of resistiveÂ
heat arenât practical on a large scale.  But heat pumps are able to turn this math on itsÂ
head. Since heat pumps, which are basically just air conditioners running in reverse, can move much more energy than they themselves consume, theyâre undoubtedly the future of home space heating. Even right now with our majority fossil-grid, they result in fewer carbon emissions than directly burning fuel because theyâre efficiency can approach 500% - more than accounting for the losses inÂ
generation. But weâll save that topic (and its current challenges) for a videoÂ
in the I Promise not-too-distant future. For now, though, back to this! One of the things weâve learned over the years as weâve embarked on this human endeavor is that burning things is unpleasant.  Burning pretty much any fuel, includingÂ
the so-called âclean burningâ natural gas  produces particulate matter which isnât greatÂ
to breathe, and of course thereâs the much more  immediately deadly combustion by-product carbonÂ
monoxide which, through evolutionary bad luck,  is much more appealing to your redÂ
blood cells than oxygen. Which is bad. So generally, we shouldnât burn things indoors. And yet, hereâs a device which burns things⌠indoors. Ah! But this particular furnace isÂ
a condensing furnace, and thanks to these two pipes here, the combustion of the fuel sort ofÂ
happens outside - but more on that later. You may also know of a certain other device which doesÂ
burn fuel indoors without ventilation - the common stovetop and oven, and research is beginning to suggest that maybeÂ
this isnât so great either, but there is the small saving grace that the quantities of fuel burnedÂ
for cooking are generally small fractions of that which a furnace uses, and also there are ways toÂ
mitigate this through ventilation but I digress. Anyway, a furnace like this needsÂ
to burn its heating fuel and then it has a bit of an exhausting job ahead of itself.  Exhausting. We want the byproducts of theÂ
combustion process to make their way outside where theyâll only be problematic in about⌠a decade orÂ
two. But of course we want to be able to extract the heat generated by the combustion process and release that into the living space. We can do that with a heat exchanger. In a typical furnace, this takes the form of a series of tubes. Actually, though! The heat exchanger in a standard 80+ furnace is simply some number of typically U-shaped steel tubes. You might call them U-tubes. The fuel is burned inside these tubes, which of course makesÂ
them get pretty freaking hot. Those tubes, then, are put in the path of
air being forced through the furnace with the aid of a blower motor, and that air keeps the heatÂ
exchanger from melting by cooling the tubes down, which also incidentally heats the air. Thatâs aÂ
nice bonus. The practical upshot of this is that the heat from the fuel gets released into the air
flowing through the furnace and eventually out of the vents which heat your home, but the combustionÂ
byproducts stay separated inside those tubes. And of course, we need those by-products to goÂ
away somehow. And also, hang on, you need oxygen to burn fuels and the burning of the fuel consumes that oxygen - so youâre gonna need a way to supply those tubes with fresh air in addition to gettingÂ
rid of the byproducts. Aha! Well now weâre getting into the more practical and safety bits of the furnace. If youâve ever lived with a furnace like this, youâll likely have noticed that there are twoÂ
blower motors. Thereâs the big one that makes air come out of your registers. But before that oneÂ
comes on, you hear another one. Whatâs that for? Well, thatâs arguably the most important partÂ
of the furnace. This blower is called the draft inducer, and really itâs more of a sucker. It pulls air - and later, other fun gasses - through the heat exchanger. In other words, it induces a draft. That air then gets pushed up through some sort of chimney where it will eventuallyÂ
exit the home, or as is the case here it exits through this PVC pipe. The draft inducer lives on the exit side of the heat exchanger, so it pulls air through the tubes, and what lives on the other side of those tubes are the flamethrowers. Now weâre getting to the burny business. If weâre burning a fuel, itâs gotta come from somewhere, and where it comes from is deep undergroundÂ
having been trapped there for millennia before we extracted it. But as far as your furnace is concerned itÂ
comes from the burners. These are essentially just specialized nozzles which release someÂ
amount of gas into the heat exchangerâs tubes.  Thanks to the constant supply of freshÂ
air brought about by the draft inducer,  it will burn quite nicely. The draft inducer ensures not only that there is fresh air for burning but also that what comes out the other side of the heat exchanger tubes doesnât make it into the living space and is instead safely expelled outdoors. Because this device deals with the, frankly,Â
dangerous combination of combustible fuels and enclosed spaces, itâs designed with a number of safety interlocks and a sequence of operations to ensure things donât go too terribly wrong. But before we get into that, I know this is the second "but before we get into that," apologies, letâs discuss the condensing part of this furnace. When you burn a fuel like natural gas, one of the byproductsÂ
is water vapor. A standard 80+ furnace doesn't really know what to make of that so sends it outÂ
with the carbon monoxide and other icky stuff. But that water vapor is hot, and more importantlyÂ
holds energy in the form of latent heat.  When it condenses into a liquid, as it willÂ
inevitably do - thatâs all the steam you see coming from the rooftops of homes in the deadÂ
of winter - it releases that energy. But thatâs no good if itâs just happening outside. If we could make it condense inside, weâd be able to get more energy out of the heating fuel. And so, a condensing furnace has what is essentially a second heat exchanger after the main fire tubes with a greater surface area that can cool the exhaust gases further which helps get more heat out of the fuel all by itself, but more importantly it gets most of the water vapor to condense and release its latent heat inside the furnace rather thanÂ
to outside air where it is otherwise wasted. Thatâs how this furnace is able to get 96%Â
of the energy available in the fuel into the  home. And itâs also how itâs able to exhaustÂ
through a PVC pipe. I mean, think about this, itâs burning flammable gas, thereâs literal fire inside of it, and it outputs 70,000 BTUS or about 20 kilowatts of heat. And yet, it loses so little of that heat in the exhaust that it can safely exit through a plastic pipe which barely gets warm at all. Compare that to an 80+ furnace with a steel exhaust chimneyÂ
that gets so hot you canât even touch it, and youâll understand why condensingÂ
furnaces are a big deal and a great idea. A condensing furnace is a little moreÂ
complicated, of course, than a conventional one.  Most of that has to do with the fact that dealingÂ
with the condensate isnât the easiest task for one, well now you have to deal with it whenÂ
previously you didnât. This furnace has a drain pipe on its side for that very reason. But also that water isnât just plain water, itâs pretty acidic thanks to other combustion byproducts so the secondary heat exchanger needs to be made of materials, such as stainless steel, which resist corrosion. This adds somewhat to the cost of the furnace, but getting an extra 10 or 15% of the energy out of your heating fuel makes it, to my mind,  obviously worth it and we absolutely shouldÂ
find ways to help subsidize the added cost  for those who need financial assistance becauseÂ
in the long run it will always save money and resources. Itâs frankly a no-brainer at this point. Oh, and that other pipe there? Well, hereâsÂ
another way to get an increase in efficiency.  This furnace gets its oxygen supply from outside. This pipe is simply supplying the combustion section with outside air, in fact you can see that it just opens to this space (and the other end is outside). Why do that? Well, a conventional furnace gets its combustion air from the room itâs sitting in. That means it creates negative pressure whenever the draft inducer is running, and that brings in some amount of cold outsideÂ
air to replace what leaves through the exhaust. In contrast, this supply pipe, along with the sealsÂ
in this panel, makes it so that the combustion section of the furnace is essentially entirely outdoors, creating no negative pressure at all. Of course, particularly right now in theÂ
human experience weâre discovering that we really ought to have a littleÂ
more exchange of air than we do. Most of our efficiency-first building practicesÂ
came about thanks to the energy crises of the seventies, and weâve been living in mostly sealedÂ
boxes which it turns out isnât super great, and not just because of respiratoryÂ
disease pandemics. Simple build-up of carbon dioxide from our exhalation canÂ
be hazardous, so some amount of negative pressure is probably a good thing and this topic deserves more attention and study. But anyway, Letâs finally bring it back to theÂ
start with one of the questions I asked;Â Â why does the furnace seem to do things in distinctÂ
steps? Ah, well thatâs all about that safety. There really arenât that many components in aÂ
basic household furnace: just the draft inducer, heat exchanger, main blower,Â
an ignitor, and a gas valve. But we absolutely need to make sure everything isÂ
in working order before we go let some flammable gas out of a pipe. And to do that, we rely onÂ
a few sensors and a sequence of operations. Since this furnace is quite modern we have aÂ
circuit board with a microprocessor handling everything, but the same basic things have beenÂ
happening in forced-air furnaces for decades. When the thermostat calls for heat, the sequence ofÂ
operations begins by turning on the draft inducer. Now, this component absolutely must be functioningÂ
properly for the safe operation of the furnace.  If it opened the gas valve withoutÂ
airflow through the heat exchanger,  it could be a disaster. So, to prove that the inducer is actually functional, the circuit board looks for the output from this pressure switch to change.  If it did, that means there was a change inÂ
air pressure where the switch is located,  which would only occur if the draft inducerÂ
is working. Looking for a change in switch output also allows the furnaceâs logic board to detect a stuck switch and refuse to operate. Once the operation of the draft inducerÂ
has been proven, there will be a pre-programmed  delay period to ensure no unburntÂ
gasses remain in the heat exchanger.  Assuming the furnace shut down correctlyÂ
there shouldnât be any, but better safe than sorry. While that delay is happening, this furnace sends power to the hot surface ignitor. This is an ignitor that ignites theÂ
fuel by being a surface which is hot. An alternative method of ignition is a sparkyÂ
thing, but that seems to have gone out of fashion for some reason.  Anyway, because it takes a while for the hot surfaceÂ
ignitor to become hot enough that its surface can ignite things, the delay period for clearing the heat exchanger is a perfect time to warm it up. Next comes the opening of the gas valve. This is a very time-sensitive step because natural gas and propane, which is actually what fuels this furnaceÂ
- Iâm really in the middle of nowhere... can be explosive! We donât want that, so we need a way to know that the fuel has actually ignited and isnât just being dumped into the heatÂ
exchanger unburnt where it could potentially go boom. And this is actually really easy to do, we just use a thermocouple as a flame sensor to detect a rapidÂ
rise in heat brought about by flames. And this is done quite cleverly. This furnace, like most, has multiple burners arranged linearly. The hot surface ignitor livesÂ
here next to the rightmost burner. The burners are designed so that a flame willÂ
quickly propagate from each one to the next, and assuming nothingâs wrong with them and that the fuel supply is adequate this should occur essentially instantly. And so, to determine that ignition happened correctly, the flame sensor is placed at the burner thatâs farthest away from the ignitor. It will thus only register a flame when all burners have successfully ignited. When the furnace opens the gas valve, it looks for a rapid rise in temperature from that sensor and it should see it right away. If it doesnât, usually within just two seconds, it closesÂ
the gas valve and aborts its mission. This checking-for-flame step is so quick becauseÂ
if any of the burners failed to ignite right away,  theyâll be pumping unburnt fuel into theÂ
heat exchanger. If thatâs allowed to happen for more than just a couple of seconds, aÂ
dangerous quantity of fuel may now exist in  the heat exchanger which, if it were to ignite,Â
would be likely to damage it. And thatâs very bad and also dangerous. So, if it doesn't see flames right away, that gas valve is closed again and the draft inducer remains running to clear theÂ
unburnt fuel from the heat exchanger. After a pre-programmed period of time, the furnace willÂ
make another ignition attempt. And after a certain number of failed attempts - itâs five in the case of this furnace - the system locks itself out and no heat for you. At least for about an hour; this furnace, and many others, will try again later because there could be all sorts of reasons for a failed ignition event, including temporary loss of gas pressure, so it does self-reset to keep your pipes from freezing if it can help it. So long as the flame sensor sensed flames, though,Â
the logic board then gives the all-clear for the next step. Which is to wait a lilâ bit. Rather than start the blower motor right away and give you a nice blast of cold air, the furnace will simply sit pretty and allow the heat exchanger to get a little hot before it switches on the blower. But once it does that, well now youâve got heat coming from your heat vents. When the thermostatÂ
is satisfied and it stops calling for heat, the gas valve closes, extinguishing theÂ
flames, and the inducer fan remains running  for thirty seconds or so to make sure all theÂ
remaining exhaust is replaced by fresh air.  At the same time, the blower motor keepsÂ
running to cool off the heat exchanger and,  of course, get the rest of the heat it containsÂ
out of it. But after about a minute, it shuts down completely and patientlyÂ
waits for the next call for heat. Now thereâs gonna be at least one otherÂ
safety device in the furnace, too,  and that would be a limit switch. This is a switch which trips at a certain temperature, and itâs designed to protect against overheating. If for some reason the blower motor stopped working, or airflow was restricted in some other way, the heat exchanger will overheat before too long becauseÂ
it doesnât have enough airflow to cool itself down.  So, that limit switch is there to detect such aÂ
scenario and shut down the furnace if it occurs. So, thereâs clearly a lot of safety built into yourÂ
typical furnace, and some clever ingenuity, too.  But thereâs one thing it generally wonât guardÂ
you from, and thatâs carbon monoxide poisoning.  If everything is in working order, that shouldnâtÂ
be possible, but⌠well whenever you burn fuel thereâs a risk of carbon monoxide. Furnaces can be particularly tricky because the heat exchanger wears out with time. Going from room temperature to having fire inside of it and back a dozen times per day for 15 years is hard on it, and over time imperfections can form from this thermal stress. The most dangerous kind is a crack in the heatÂ
exchangerâs tubes, which can allow exhaust gasses - and thus carbon monoxide to exit theÂ
heat exchanger and make it into the living space. This is why it is vitally important that youÂ
have carbon monoxide alarms in your living spaces, and especially in your bedrooms. Carbon monoxide poisoning is a rare thing, but an alarm is the only thing that can guard you against it. Annual furnace inspections by a trained technician may be able to catch problems before they become dangerous, but accessing the heat exchanger for a thoroughÂ
inspection can be difficult and might not be performed in your typical âpre-season tune-up special.â So please, if your home is heated by combusting fuel - even if itâs not a forced air furnace but instead something like a boiler or indeed, even if fuel is burned anywhere in your home for cooking or water heating or anything, invest in carbon monoxide alarms andÂ
test them regularly. They may just save your life. So, thatâs how your typical North American gas-fired
forced-air furnace works. Itâs really pretty simple, but thanks to modern technology,Â
quite efficient, too. On that note, condensing heat exchangers arenât limited by any means to forced-air furnaces. Boilers can take advantage of this tech, even water heaters! So long as natural gas or other fuel combustion remains a prominent form of space and water heating, we really ought to do it as efficiently as we can. However, as we move headfirst into this decade,Â
weâll undoubtedly start to see natural gas become phased out in more and more places. In areas with mild heating needs, heat pumps are already viable with little more investment than an air conditioner. And for colder climates like mine, geothermal heat pump systems are available andÂ
are dropping in price fast. But weâll get into those weeds maybe in a month or two. Perhaps three. It will be this heating season. Iâve got a thermal camera, now, and thereâs a reversibleÂ
minisplit the garage so - no excuses. OK bye. ⍠efficiently smooth jazz ⍠Eugh, this is a clunky line. Pretty much ever small-to-medium-sized building built over here geh gu, ugh... Nope, that's not the line I wrote! ...immediately deadly combina - combustion. Dangit! And of course, there's the much more immediately deadly combustion byproduct carbon monoxide whi --- ohhh, carbon wasn't said right! "ca ma ma ma fehhhhr" ...path of the air being forced through the furnace with the aid of a blower *motor* Ehh... blower *motor*.
[clears throat] That's... with a *blower* motor. Blower *motor* is stressing the wrong thing. ...with a greater surface area that can cool the exhaust gasses further which helps gets more heat out of the help ef frark! Yes, our furnaces don't smelt anything or really have much of a connection to metallurgy at all. Such is the terrible realm of regional jargon. At least they have something to do with heat! I mean, we could call them "dog kennels" so, hey.
Cold air intake, bro! Cold air intake for your furnace, bro!
Very nice video. You have a good way of explaining things in an easy, yet technical way :)
Regarding the flame sensor:
You've already stated it's not a thermocouple. However the flame is not acting like a diode either.
The flame contains charged particles (ions). The more ions you have, the less electrical resistance you'll get. This is like putting more salt in water.
So the flame sensor is literally a piece of metal, connected to a high resistance measuring device.
.
This guy modified a usual multimeter to measure high resistances (The voice is in german, but you can see the measurement. It was the only video I could find with someone measuring a flame resistance):
https://youtu.be/BtrHDTZJOSA?t=547
.
As you can see, as soon as the flame pops up the voltage also goes up (which means the resistance between the metals dropped, because of the flame).
Thank you for this incredibly informative video! I knew there were more efficient furnaces out there, but I did not know how they worked. I am currently getting a Tesla solar roof installed. My ultimate goal is a heat pump, but I'm not sure if they make sense here. Do you know if there are whole house heat pumps with backup resistive heating? If not now would be a great time to get an extra vent put in for a condensing furnace.
As someone with a mechanical engineering degree for HVAC systems I approve this message. đ
Thanks a lot for this video. As a person moving from a tropical country to Canada I had many questions in my head about home furnaces and how it works.
Here in Sweden, I'm mainly used to electric resistance heating, heat pumps, and most commonly, district heating, where a facility (usually at the edge of town) burns something to make large amounts of hot water which is then pumped to homes. (This also provides hot tap water).
yay
You might call the âu-tubes.â đ¤Ł
I'm from europe and have never seen such a heating system (here all burners heat up a boiler with water, which will then get pumped to radiators in the rooms).
What happens if my room is at 20°C, but I want it to be heated to 22°C. Can the system allow just a little bit of air to enter the room, or is the system constantly going off and on?