Analog Output Scaling || TIA Portal || 4-20 mA / 0-10 V

Video Statistics and Information

Video
Captions Word Cloud
Reddit Comments
Captions
hello friends welcome to Simmons programming tutorial today we will learn analog output programming in TI a portal so which are the analog output devices it's like control wall-e which it could be a hydraulic control or pneumatic control all right then we have D control to change the speed of here B we change the frequency and we could done this by analog output from plc we will fire the analog output and based on that the VFD frequency will be change so we have D control and AI do all which open in percentage based on the analog input right so we will take an example for today's program that is we have disparate control so we change the frequency between 0 to 50 Hertz for changing the speed of the PFD right and the input of this VF d D 0 to 10 volt ok so go to TI putin first we will add hardware to analog output put a hardware part low EQ select your analog output model you catalog number ok suppose we have to channel it you take the address for these go to properties okay the type of analog output model is voltage so we have also the voltage type right zero to ten hold so no change here and address of output is qw 1 4 4 okay then we will write code last time housing analog input now we see oh okay taking d-block No X what is over range now 0 to 5000 frequency we need to change the frequency between 0 to 50 Hertz so we have taken minimum zero maximum 50 here we will create one tag index kill now the value should be zero to three to seven six seven openness and if so we will take one toggles for now what is the address of output q w1 okay start simulation lord at an assimilation money does okay this is all actually or analog output both rich and this is our frequency with so we'll change this frequency we found hero 250 Green so hoodies 65536 for you for 320 so we for we on 20 frequency will put here 20 and output will go to 13 1 0 say one based on this the voltage will be given to V of D 40 so in this way we can change the frequency and based on that the output voltage will be very op 50 it will be maximum will be three two seven six seven okay thank you for watching in video friends
Info
Channel: Industrial Automation
Views: 5,115
Rating: undefined out of 5
Keywords: Analog Output scaling in TIA Portal, Analog scaling in TIA portal, Analog programming in TIA Portal, Analog output programming in TIA Portal, PLC Programming tutorial for beginner, TIA Portal tutorial for beginner, Siemens programming tutorial for beginner
Id: OK-HuGoce_w
Channel Id: undefined
Length: 8min 11sec (491 seconds)
Published: Mon May 11 2020
Related Videos
Note
Please note that this website is currently a work in progress! Lots of interesting data and statistics to come.