Top 5 Residential Electrical Code Violations

Video Statistics and Information

Video
Captions Word Cloud
Reddit Comments
Captions
[Music] [Music] welcome back to the channel my name is ronal more with PPG and if you are new to the channel come on subscribe hit that notification Bell so you'll know when these heaters are dropping today's topic all about electrical top five electrical code violations this violations that I come across every single week day in day out you're on the job so sit back relax and enjoy and I'll see you again in the next one all right we're doing an electrical final new meter there's my ground wire uh the issue is the the inner system bonding terminal bar that's for the low voltage for cable you know internet uh phone that bonding terminal bar typically is it's secure right in that area uh that one is missing that is is in the code book anyc and he also didn't secure the mask down to the meter we got one screw that's halfway pretty much out and we got one missing in the back two on the other side that are missing so that mask is not even secured down to the meter today's issue is the working space around an electrical panel let me try to get around so you can look at that but that's your your panel there that's the panel there and they chose to put this panel in a closet I don't know why but does that look like the required working space around a panel I think not it's a very very small closet that they put this 200 amp panel in for these AC condensing units make sure you check the label on these see I still run across a lot new construction all Outlets all receptacles must be tamper resistant all new receptacles all new electrical outlets must be tamper [Music] resistant this is one that I still still see a lot of that I shouldn't really um the all electrical outlets receptical outlets in the bathroom must be on the GFC circuit um one little tester here it is wired correctly you see there but when I hit my test button to see if it'll trip the GFI trips it doesn't it doesn't trip all receptical outlets and bathrooms kitchen must be on GFCI circuit kitchen laundry GFCI and afci this one is not tripping you can see I pressed the little button here and it's not tripping the bathroom brand new [Music] home [Music]
Info
Channel: PPG
Views: 97,040
Rating: undefined out of 5
Keywords: 2020 NEC, Electrical Code Violations
Id: Q2TXesCpHZY
Channel Id: undefined
Length: 5min 6sec (306 seconds)
Published: Wed Jun 29 2022
Related Videos
Note
Please note that this website is currently a work in progress! Lots of interesting data and statistics to come.