Pressure Regulators for Regular People

Video Statistics and Information

Video
Captions Word Cloud
Reddit Comments
Captions
the knob will adjust the delivery pressure turning the knob clockwise will increase the delivery pressure cylinder gauges are normally 3000 or 4000 psi the maximum delivery pressure is typically in the middle range of the delivery pressure gauge this is the bonnet which holds the spring when the regulator hand knob is turned the spring is compressed the spring displaces the diaphragm the diaphragm then pushes on the valve poppet causing it to move away from the valve seat door ffice becomes larger in order to provide the pressure and flow required the bonnet has a vent hole which is a safety feature that protects the bonnet from overpressurization if there's ever a leak past the diaphragm the bonnet vent hole should never be plugged many of our pressure regulators have a sticker over the bonnet vent hole which will blow off easily should gas need to escape through the bonnet vent hole the CGA designation number is engraved on the nut CJ 580 is for inert gases like nitrogen helium and argon a CGA 350 fitting has notches on the nut which shows that the nut has left handed threads CGA 350 is for flammable gases like hydrogen methane and carbon monoxide CGA 350 and CGA 580 fittings have bullet nosed nipples the CGA 320 fitting for carbon dioxide cylinders has a flat faced nipple and needs a washer many of our regulators have full turn diaphragm valves some regulators have a multi turn needle valve which offers better flow control over a full turn diaphragm valve but does not offer the same level of purity this outlet fitting is a quarter-inch compression fitting for rigid tubing the CGA fitting is in a high pressure port marked with an H the outlet valve is in a low pressure port marked with an L this is a single-stage regulator and this is a dual stage regulator dual stage regulators are like two regulators in one body and will offer a more stable delivery pressure over to life of a cylinder the first stage of a dual stage regulator is set for about 300 psi most single stage regulators have two 1032 mounting holes in the back typically spaced seven eighths of an inch apart
Info
Channel: Matheson Specialty Gas Equipment Tech Support
Views: 3,894
Rating: 4.7714286 out of 5
Keywords:
Id: 5zevs7Ui4vE
Channel Id: undefined
Length: 3min 29sec (209 seconds)
Published: Sun Oct 06 2019
Related Videos
Note
Please note that this website is currently a work in progress! Lots of interesting data and statistics to come.