hello Hank so my name is Ren and today i show you how to conclude scout with somatic 3 and restriction first of all open the somatic manager software file let's create the new project you given your project name this is server client and select the path I have already designed one folder just click and ok ok now your project is created open the project usage the first new object and select the somatic 3 in distinction because other hardware is is 300-series PLP now click on the somatic theory initiation this is one option shows the hardware open the hardware option so first we will configure the hardware the first of all this is the task our somatic 300 option open the 300 option the second last option drag first insert the rack and open the CPU 300 or part number is a 3 1 4 C 2 P and 60p select and drag and drop in second slot because first slot is reserved for the power supply okay here a sense for your PLC IP and now generate the communication does I just given the name there is the fill pulse and ok now your bus is generated I place the created just save and compile ok and download this one option is pop up it is a selected node address in this window your software we will configure the IP in software they mentioned and there is a one option for accessible node an accessible node you will see actual physical pdip showing the accessible node just wait for some time okay so this is my IP and just view the current we will see IP showing the accessible node the first we will match your software IP and the physical IV okay both are the same now okay and let's click ok so now your views you can provision is completed seven configure and close this window now we will configure the server contribution again click on the project inside the new object and the somatic three under station sorry nakta matrix registration just click insert the somatic registration and this is station configuration interval swag this is in task card the last option the somatic participation open and one option are the CP industrial Ethernet card because our communication protocol is the protein it means in this realization it so first I will add the I in digital card and this IP is same as is really your system IP we call my system IPS right now is the 32 because this system I have used as in my OPC server so definitely I first match your system ID with this IP and select this filmers this is the communication with the system to PLC and choose an application opposite servers and opposite server now OPC server is installed again seven compile and download okay just see the offline name is the somatic registration and online name is the tail PC so this is the warning symbol this is not a major issue but how to match this both I show you in the one option first download okay let's wait for some time okay so now your hardware contribution is completed here I have designed the gist one program only one just simple trial here I have considered one input is M memory area I'm zero point zero and this is output q1 36.0 the before we will consider we will use in this server we need to first define the symbol in this stack table so just right click on the tag and edit symbol just click on the symbol this is the start bit i just given the name as a start bit okay and this one is i give us the name as a mortar i just given the name it is a mortar output motel Opie okay and save in just download the tree under station okay now after computation of the hardware and the program open the next row this contribution network option so here we will configure the network the first just click in the OPC server first in the CPU three in gestation there is a local ID click on the connection and select your partner it is OPC server and see this connection it is at seven connection and now okay now establish the connection okay the connection is the consider but we will read the data to be Elsie to server the first need to configuration of the server it is click on the OPC server right click on the opposite service objects the property there is no one option as seven and first its access protection active means write read read and write both option are active now consider and see this option is available open this option this is a your project is show in this area open your PLC the mention two tags are already show here and this press ok ok so this contribution is completed now one man one download this hydrogen with this network contribution firstly ended countries are completed now obviously our contribution is completed download and ok just wait for some time II okay so now network contribution is completed the first open the station contribution option and see these two options of the server the run and stop it is a running and the connection is the consider means your opposites are or is working so now first open the your server is the opposite shout OPC Scout and select the option of this is schematic not because of some solution particular is a PROFINET so open this one and second last option is the system there is a somatic surrender station and as your PLC just click in there the two over tags are there and just drag and drop in this down table counter table this is option monitoring on ok now now you see the both tags our values is false so this is the tag is the mine I have designed the simple ladder logic bit and a contact with my coil so I just on this coil ok and I will just select this see okay this I stopped now again i insult first start bit second water output okay and now monitoring on both our fold so your first bit is your first bit is start bit okay I just change the value is it true okay and threat you just see it put it on your output is work and just check it out of the program open the your b1 and the monitoring to see your output is on now again open the position well I just again change as a false okay and right both are off and just see this your output is off so this is a contribution of the opposite server with the symmetric 300 station thank
Info
Channel: All About Industrial Automation
Views: 34,561
Rating: undefined out of 5
Keywords: PLC, S7 PLC, Siemens PLC, OPC scout, OPC scout configuration, Siamtic manager, S7 PLC and OPC SCout, opc server, plc and opc server, OPC server configuration, OPC configuration in simatic manager
Id: SpNNXxD0xVA
Channel Id: undefined
Length: 9min 37sec (577 seconds)
Published: Thu Jan 12 2017
Related Videos
Note
Please note that this website is currently a work in progress! Lots of interesting data and statistics to come.