การต่อสายไฟฟ้า ตู้ Consumer บัสบาร์เดี่ยว MAIN RCBO แบรนด์ Schneider

Video Statistics and Information

Video
Captions Word Cloud
Reddit Comments
Captions
Hello, in this VDO I will introduce the wiring of Consumer unit single busbar MAIN RCBO brand Schneider electric. This VDO will be an installation according to electrical standards for Thailand. consumer unit inside the cabinet will consist of electric main breaker The main breaker has a type of MCB that will cut the circuit when a short circuit occurs. and cut off the circuit when the current is overloaded and the RCBO type has short circuit protection, over current protection and leakage current protection. will trip within 0.04 seconds At the RCBO there is a Test RCD button. Next will be circuit breakers for electrical branch circuit breakers such as lighting circuits, receptacle circuits, air conditioning circuits. and water heater circuit, etc. Next will be the Neutral busbar. Next will be the ground busbar. Low voltage wire color standard, 1 phase 2 wire system 230 VAC Phase wire - Brown / Neutral wire - Blue / Ground wire - Green or Green with yellow stripe set to the same standard Low voltage mains feeder wiring The size of the electrical mains and the size of the ground wire Adhere to local electricity requirements. Phase wire from pole L of KWH Meter to pole L on power input side of RCBO Neutral wire from N terminal of KWH Meter to ground busbar. Next, install the neutral wire from the busbar ground to the N terminal on the power input side of the RCBO Will not connect the neutral wire from the KWH meter to the N terminal of the RCBO. wrong installation method Correct installation method Grounding Lets you wire from the ground busbar. come to the ground rod The rod is 5/8" in diameter and 2.40 m in length. The rod is driven into the soil. Receptacle wiring The phase wire from the branch breaker to the L terminal of the electrical outlet. The neutral wire from the neutral busbar to the N terminal of the electrical outlet. The ground wire from the ground busbar to the G terminal of the electrical outlet. Lighting wiring Phase wire from the branch breaker to the electrical switch. The phase wire from the electrical switch to the L terminal of the luminaire. The neutral wire from the neutral busbar to the N terminal of the luminaire. Air condition wiring Phase wire from the branch breaker to the L terminal of the condensing unit. Neutral line from neutral busbar to N terminal of condensing unit. Ground wire from busbar ground to terminal G of the condensing unit. The AT rating of the branch breaker and the cable size. Must be suitable for the BTU of the air condition to be installed. Water heater wiring The phase wire from the branch breaker to the L pole of the water heater. The neutral wire from the neutral busbar to the N terminal of the water heater. Ground wire from the ground busbar to terminal G of the water heater. The AT rating of the branch breaker and the cable size. Must be suitable for the Watt of the water heter to be installed. Hope this VDO is useful for you.
Info
Channel: THE KOP ENGINEER
Views: 466,986
Rating: undefined out of 5
Keywords: consumer, consumer unit, คอนซูเมอร์, ตู้คอนซูเมอร์, ต่อสายไฟฟ้า, ต่อสายไฟตู้คอนซูเมอร์, ต่อสายไฟตู้consumer, ต่อสายเมนไฟฟ้า, สายเมนไฟ, สายเมนไฟฟ้า, วงจรไฟฟ้า, วงจรแสงสว่าง, วงจรเต้ารับ, วงจรเต้ารับไฟฟ้า, เต้ารับไฟฟ้า, วงจรเครื่องทำน้ำอุ่น, เครื่องทำน้ำอุ่น, ต่อวงจรเครื่องทำน้ำอุ่น, แอร์, วงจรแอร์, ต่อสายดิน, สายดิน, สายกราวด์, ตู้ไฟฟ้า, ตู้ไฟในบ้าน, ตู้เมนไฟฟ้า, เมนเบรกเกอร์, ต่อวงจรเมนไฟฟ้า, การต่อสายเข้าตู้คอนซูเมอ, ต่อสายเข้าตู้ไฟ, บัสบาร์เดี่ยว, เบรกเกอร์, เบรกเกอร์ไฟฟ้า, สายนิวทรัล
Id: I4YzwD0oWg4
Channel Id: undefined
Length: 6min 53sec (413 seconds)
Published: Wed Jan 08 2020
Related Videos
Note
Please note that this website is currently a work in progress! Lots of interesting data and statistics to come.